STATION
-
Lithium battery (LiIo/LiPo/LiFe) program
These programs are only suitable for charging and discharging
Lithium batteries with a nominal voltage of 3.3V, 3.6V or 3.7V per
cell. These batteries need to adopt different charge technique is
termed constant voltage(CV) and constant current (CC) method.
The charge current varies according to the battery capacity and
performance. The final voltage of charge process is also very
important, it should be precisely matched with the charged
voltage of the battery. They are 4.2V for LiPo, 4.1V for LiIo and
3.6V for LiFe. The charge current and nominal voltage as for cell-count set on the charge program must
always be matched with the battery being charged.
Select the output channel that the program will be performed by pressing ‘CHANNEL button. Then, select
one of the program which suits the type of battery being processed using UP/DOWN’ button and press
‘START/ENTER’ button to enter the program.
Charging Lithium battery (LiIo/LiPo/LiFe)
!
PROGRAM SELECT
CH2>
LiPo
LiFe
LiIo
NiMH
NiCd
Pb
SETUP
REVIEW
Chg curr : 5.0A
Chg mode : Normal
End curr : Auto
Chk time : 10min
Max capa : 100%
LiPo[ 1 ] 6S(22.2V)
3000mAh CHARGE
- Charge current : Set the charge current. (0.1 ~ 9.0A)
Chg curr : 5.0A
Chg mode : Normal
End curr : Auto
Chk time : 10min
Max capa : 100%
LiPo[ 1 ] 6S(22.2V)
3000mAh CHARGE
You can choose a sub-program to be performed by pressing
‘MODE’ button, there are ‘CHARGE’, ‘DISCHARGE’ and
‘STORAGE’ programs. And then select the data number which
will newly set up, or load the data number already set up for
re-use using ‘INC’ or ‘DEC’ buttons. If you have the set-up data
which had been performed successfully before, you can just start
the process after loading the data number. All setup data will be
stored at charger’s memory automatically after setting them all.
Input the cell-count and capacity of the battery will be charged.
The cell-count and capacity need to be matched with the battery.
Use ‘UP/DOWN’ buttons to scroll up and down the menu, and
change the value using ‘INC/DEC’ buttons when the pertinent
field is blinking.
To start the process, press and hold ‘START/ENTER’ button for
more than 3 seconds regardless of cursor position.
Set : 6S(22.2V)
Read : 6S(22.2V)
LiPo[ 1 ] 6S(22.2V)
3000mAh CHARGE
Confirm(ENTER)
This shows the number of cells you set up and the charger
detects. 'Read' shows the cell-count found by the charger and
'Set' is the number of cells selected by you at the previous
screen. If both numbers are identical you can start charging by
press ‘START/ENTER’ button. If not, press ‘STOP/ESC’ button
to go back to previous screen. Then carefully check the number
of cells of the battery pack again.
!