Vue de la page 19
e
STATION
-
!
!
- 20 -
Review the data after finishing the process
(1) Output voltage : Shows the DC voltage at the output on end of
process.
(2) Charged or discharged capacity
(3) Time : Records the amount of time in minutes, which needed
to complete the process, not counting the time in trickle charge.
(4) Output channel mark : The output channel which the process
had been performed.
(5) The graph shows the voltage curves in Y-axis along with the
time in X-axis, after the process has finished.
UP/DOWNUP/DOWN
After finishing the program, you can review the data which
had been pertained to the input and output of the charger by
selecting menu at the main screen.
These data can not be shown while the program is being on
process.
The display shows the final voltage of individual cells, when the
balance tab was connected to the individual port of charger
during the process of Lixx battery. ith balance mode.
1
2
3
4
DAT GRP CYE CEL
10.54V 898mAh 52m
DAT GRP CYE CEL
Input vol : 12.35V
Output vol : 10.54V
Ext. temp : 42C
Chg time : 52min
Dchg time : 0min
Capacity : 898mAh
DAT GRP CYE CEL
No Capacity Voltage
1 C 00000mAh 0.00V
D 00000mAh 0.00V
2 C 00000mAh 0.00V
D 00000mAh 0.00V
DAT GRP CYE CEL
No Vol No Vol
UP/DOWNUP/DOWN
UP/DOWNUP/DOWN
PROGRAM SELECT
CH2>
LiPo
LiFe
LiIo
NiMH
NiCd
Pb
SETUP
REVIEW
!
!
REVIEW
5
Input vol : DC voltage at the charger’s input lead.
Output vol : DC voltage of battery at the end of process.
Ext. temp. : The temperature of battery as measured with
temperature sensor connected to temp. port of charger at the end
of process.
CHG time : The total amount of time needed to complete charge
process.
DCHG time : The total amount of time needed to complete
discharge process.
Capacity : The total amount of charged or discharged capacity for
whole process.
This display shows the battery’s capacity and peak voltage
readings for each charge and discharge period for up to 10
cycles. The cycle number is show on the left side of the display.
Pressing ‘INC’ or ‘DEC’ button will scroll the display up and down.
Charge data is marked by ‘C’ and discharge data is marked by
‘D’.
C1: 4.20V C5: 0.00V
C2: 4.19V C6: 0.00V
C3: 4.20V C7: 0.00V
C4: 0.00V C8: 0.00V
!